Heat Tape Controller Remote Display Panel (CDP-2)

Snow sensor display panel for use with the DS8 & DS9 heat tape controllers. Convenient Indoor Monitoring & Control – Self Powered, No AC Wiring or Batteries Required – Fits Standard Single Gang Electrical Box.

  • For use with CS-50 and CS-100 low voltage cable
  • Convenient way of monitoring your heat cable control system from inside your home
  • Installs in any standard single gang switch box with standard cover plate

$119.72

11 in stock

FREE Shipping

Product Details

Heat Tape Controller Remote Display Panel (CDP-2)

The CDP-2 Snow Sensor Control/Display Panel is used in conjunction with a DS8 and DS9 Series Heat Cable Controller. The CDP-2 provides a method of remotely monitoring and controlling the attached sensor. The user may monitor both the operating mode and the activation state of the heat cable control system. The CDP-2 derives its power from the snow sensor and requires no batteries or AC power. With an operating temperature range of -40°C to +85°C the CDP-2 is designed for use either indoors or outdoors with proper protection from the elements.

5/5

“Heat Tape Pro did exactly what I needed it to do. Now I don’t have to worry about water leaking into my house, because I can tell when it’s working by the little light on the end of the cable.”

-Michael P.
Amazon Customer

4/5

“This heat tape works as advertised. It was delivered to me fast, and although it’s a little complicated to install, the documentation is good..”

-Shaun D.
Radiant Solutions Customer

5/5

“I install thousands of feet of heat tape every year. This is the best stuff I’ve found to protect my customers homes and give them the piece of mind they need.”

-Patrick B.
Professional Installer

Frequently Asked Questions

The type of clip you need for your heat tap installation is based on what kind of roof you have.

We are building a hand guide to identify what kind of roof you have and find the clips that can/should be used with that roof-type.

View the Guide Explaining What Clips You Need Here

To know how many clips you need to buy, there are two things you need:

  1. Some Basic measurements regarding your installation area & some considerations to note
  2. Our handy Heat Tape Calculator to punch in your measurements & notes

We have a guide on How to Measure for Purchasing Heat Tape that will help you. Once you have your measurements, you can find our Heat Tape Calculator here.

Yes. Heat Tape Pro can be used on your flat roof and will not harm the roofing material.

Radiant solutions has developed several accessories and installation components that work well for flat and low-pitch roofs. Installing heat tape on a flat roof often requires more unique considerations than standard serpentine patterns used on pitched roofs.

Check out our Case Studies for examples of Heat Tape installations, including information on flat roofs.

Also refer to the Heat Tape Pro Product Manual for information on flat roof installations of heat tape.

Yes We Do. However, it is fairly costly.

We have a calculated rate based on the product in your cart if you choose to ship to Canada or Alaska.
More can be found here.

No plug-in ready Heat Tape should be cut, modified or altered.

Heat Tape Pro and Pipe Freeze Pro are offered in many lengths from 6-foot up to 150-foot. These products are not designed to be modified, so you should pick the length you need and work with that length. These cables should not be altered and doing so would void any warranty on the product.

Radiant Solutions DOES offer heat tape on spools that can be cut to any length by you.

We offer heat tape on spools from 250-foot to 1000-foot. These spools are designed to be cut to length, made into multiple cables, etc. Heat Tape on spools needs to be hard-wired into a junction box, or have a power connection plug-in manually added to it for use. It also requires ends to be properly sealed and terminated. When working with Heat Tape on spools, a Licensed Electrician should be utilized to assure proper wiring per regional codes and standards.

Including a thermostatic heat tape switch or controller in your installation will cut power to your heat tape in times it is not needed. This will lessen your environmental footprint and save you money.

Savings will always depend on the weather and how often you have temperatures above the threshold that the switch turns on your heat cable. In most situations where heat cable is needed, savings will offset the cost of the ThermaCord and then some.

The short answer is NO. Self-regulating heat cable does not turn itself on and off automatically. To do that you need to put the cable on a switched circuit or outlet or on a controller. Of course, you can also be old-school about it and simply plug and unplug as needed. 

“Self-Regulating” refers to the fact that these cables are temperature sensitive. Due to their construction, these cables sense changes in temperature along their entire length, demanding more power as temps fall and less when they rise. 

PipeFreeeze Pro™, Pipe Freeze Protection Solution has a built in thermostatic switch, meaning it will turn on and off on it’s own.

Heat Tape Pro™, does not contain a built-in thermostatic controller. We recommend adding the ThermaCord™ Thermostatic controller to turn your Heat Tape PRO to turn the cable on and off with changes in temperature.

Radiant Solutions products, including Ice Dam Prevention products such as Heat Tape Pro and Pipe freeze Prevention products like Pipe Freeze Pro can be purchase here at this website or at Amazon.com.

There is no difference.

The terms heat cable, heat tape and heat trace are all used interchangeably to described heated cables used to protect pipes from freezing, preventing roof and gutter ice dams from forming and for safeguarding temperature sensitive components.

Other terms we’ve seen used regarding Heat Tape are:

  • Heat Coils & Heating Coils – Heat Tape has been called this because of the way the zig-zag pattern looks like a heating coil-element (like inside of a toaster)