S-5-S Standing Seam Clamp

Heavy Duty Clamp of Standing Seam Roofs

The S-5-S is a base-clamp used for mounting on standing seam roofs. For installation of Ice Dam Heat Tape, use along with our S-5 SR Clip.

  • Use on vertical snap-together profiles
  • Use on single-folded with horizontal projection ≤ 0.54” (13 mm)
  • Two T-30 Torx round-point setscrews (Torx bit tip provided)
  • One M8 bolt included

$9.50$239.95

FREE Shipping

Product Details

S-5-S Standing Seam Clamp

The S-5 is the preeminent solution for any mounting application on standing seam roofs. Combined with our S-5 SR Heat Tape Clip, ice dam heat tape can easily be mounted to your standing seam roof. Using the S-5 SR Clip your heat tape is re-positionable and doesn’t require any tools to loosen or alter the position of your heat tape.

The S-5-S (“S” stands for snap-lock) is a non-penetrating, standing seam metal roof (SSMR) clamp. The S is designed for most popular vertical snap-together profiles — typically with vertical dimensions of 1.5” (38 mm) and 1.75” (44 mm).

The S is also the perfect solution for traditional, single-fold (angle-seam) horizontal profiles of 1” (25 mm) and 1.5” (38 mm) seam height dimensions and all similar seam types.

Does the S-5-S Fit Your Roof Profile?

In order for the S-5-S  to fit the types of seams illustrated below, the finished seam must:

  • Be at least 1” high
  • Have a finished seam thickness ≤.54” (13 mm) for snap-lock type profiles
  • Have a horizontal seam dimension ≤.54” (13 mm) for single-fold type profiles
  • Have a male seam height sufficient for the clamp setscrews to fully engage both male and female seam portions together

Installation

Installation is as simple as placing the clamp on the seam and tightening the round point Torx Drive (T30) setscrews to the specified tension. Then, affix ancillary items using the included bolt. (See Linked Installation Manual Above)

5/5

“Heat Tape Pro did exactly what I needed it to do. Now I don’t have to worry about water leaking into my house, because I can tell when it’s working by the little light on the end of the cable.”

-Michael P.
Amazon Customer

4/5

“This heat tape works as advertised. It was delivered to me fast, and although it’s a little complicated to install, the documentation is good..”

-Shaun D.
Radiant Solutions Customer

5/5

“I install thousands of feet of heat tape every year. This is the best stuff I’ve found to protect my customers homes and give them the piece of mind they need.”

-Patrick B.
Professional Installer

Frequently Asked Questions

We don’t install heat tape, but we know who does.

We work with licensed roofers, electricians and other contractors as Installers of Radiant Solutions Products. We know of installers all over the country.

If you are interested in finding a Heat Tape PRO™ installer in your area, click here to submit your info. If we have an installer we know of in your area, we will send you a recommendation.

Yes. Heat Tape Pro can be used on your flat roof and will not harm the roofing material.

Radiant solutions has developed several accessories and installation components that work well for flat and low-pitch roofs. Installing heat tape on a flat roof often requires more unique considerations than standard serpentine patterns used on pitched roofs.

Check out our Case Studies for examples of Heat Tape installations, including information on flat roofs.

Also refer to the Heat Tape Pro Product Manual for information on flat roof installations of heat tape.

There is no difference.

The terms heat cable, heat tape and heat trace are all used interchangeably to described heated cables used to protect pipes from freezing, preventing roof and gutter ice dams from forming and for safeguarding temperature sensitive components.

Other terms we’ve seen used regarding Heat Tape are:

  • Heat Coils & Heating Coils – Heat Tape has been called this because of the way the zig-zag pattern looks like a heating coil-element (like inside of a toaster)
  • Gutter Trace – Heat Tape get’s called this because of the usage in and around gutters

No plug-in ready Heat Tape should be cut, modified or altered.

Heat Tape Pro and Pipe Freeze Pro are offered in many lengths from 6-foot up to 150-foot. These products are not designed to be modified, so you should pick the length you need and work with that length. These cables should not be altered and doing so would void any warranty on the product.

Radiant Solutions DOES offer heat tape on spools that can be cut to any length by you.

We offer heat tape on spools from 250-foot to 1000-foot. These spools are designed to be cut to length, made into multiple cables, etc. Heat Tape on spools needs to be hard-wired into a junction box, or have a power connection plug-in manually added to it for use. It also requires ends to be properly sealed and terminated. When working with Heat Tape on spools, a Licensed Electrician should be utilized to assure proper wiring per regional codes and standards.

Yes!

And if you are using Heat Tape Pro on your roof / eave to resolve an ice dam issue, you should use heat tape to make sure there’s a clear path through your gutters for water to escape your roof. If you don’t do that, the water could just refreeze in your gutters. You also want to get the downspouts too.

Be careful if you plan on using heat tape Only in your gutters.

There is a common misconception that gutters are a root cause of ice dams. This misconception can lead people astray when creating their strategy for ice dam deterrence. If you have an overhang on your roof (an eave), the chances are very good that you problem exists on your roof before the gutter.

Learn More about How Ice Dams Form Here

The type of clip you need for your heat tap installation is based on what kind of roof you have.

We are building a hand guide to identify what kind of roof you have and find the clips that can/should be used with that roof-type.

View the Guide Explaining What Clips You Need Here

To know how many clips you need to buy, there are two things you need:

  1. Some Basic measurements regarding your installation area & some considerations to note
  2. Our handy Heat Tape Calculator to punch in your measurements & notes

We have a guide on How to Measure for Purchasing Heat Tape that will help you. Once you have your measurements, you can find our Heat Tape Calculator here.

The short answer is NO. Self-regulating heat cable does not turn itself on and off automatically. To do that you need to put the cable on a switched circuit or outlet or on a controller. Of course, you can also be old-school about it and simply plug and unplug as needed. 

“Self-Regulating” refers to the fact that these cables are temperature sensitive. Due to their construction, these cables sense changes in temperature along their entire length, demanding more power as temps fall and less when they rise. 

PipeFreeeze Pro™, Pipe Freeze Protection Solution has a built in thermostatic switch, meaning it will turn on and off on it’s own.

Heat Tape Pro™, does not contain a built-in thermostatic controller. We recommend adding the ThermaCord™ Thermostatic controller to turn your Heat Tape PRO to turn the cable on and off with changes in temperature.

Yes. Radiant Solutions Company is based in Hopkins, Minnesota.

We are a family-owned business with less than 10 employees that has been in business since 2016. Our experience with ice dams goes far beyond that: our founder Steve started a business diagnosing and solving Ice Dam problems on customer houses for almost 35 years.