Standing Seam Metal Roof Clips 10-Pack

For Installing Heat Tape on Standing Seam Roofs

10-Pack of Roof Clips for Mounting Heat Tape to Standing Seam Metal Roofs .325″ to .625″.

$24.50

FREE Shipping

Product Details

Standing Seam Metal Roof Clips 10-Pack

This clip comes in three different sizes in packs of 10. The standing seam clip is designed to provide a strong attachment point for installing heat cable on most common standing seam metal roofs. Please verify the width of your standing seam to determine which clip size you need. The standing seam metal roof clip requires a seam with a minimum height of 1 1/4”. Tools Required: Screw gun, Hex head driver bit(5/16”), Butyl Pads(best method for sealing screws), or Silicone caulk.

Clip Facts:

  • UNIVERSAL: Compatible with all manufacturers of ice dam prevention heat tape
  • INCLUDED: 20 Qty Sheet metal screws (2/per clip)
  • CONSTRUCTION: Robust aluminum anodized black. 
  • WARRANTY: Best in the industry 10-year warranty on residential or commercial applications 
  • FAST: Each clip roughly installs in under a minute when using our butyl pads

Important:

  • .325″ Standing Seam metal roof clips should only be used on standing seams between ⅛” and ⅜.”
  • .500″ Standing Seam metal roof clips should only be used on standing seams between ¼” and ½.”
  • .625″ Standing Seam metal roof clips should only be used on standing seams between ½” and ⅝.”
5/5

“Heat Tape Pro did exactly what I needed it to do. Now I don’t have to worry about water leaking into my house, because I can tell when it’s working by the little light on the end of the cable.”

-Michael P.
Amazon Customer

4/5

“This heat tape works as advertised. It was delivered to me fast, and although it’s a little complicated to install, the documentation is good..”

-Shaun D.
Radiant Solutions Customer

5/5

“I install thousands of feet of heat tape every year. This is the best stuff I’ve found to protect my customers homes and give them the piece of mind they need.”

-Patrick B.
Professional Installer

Frequently Asked Questions

Yes. Radiant Solutions Company is based in Hopkins, Minnesota.

We are a family-owned business with less than 10 employees that has been in business since 2016. Our experience with ice dams goes far beyond that: our founder Steve started a business diagnosing and solving Ice Dam problems on customer houses for almost 35 years.

Yes.

Radiant Solutions has the most comprehensive installation system for Heat Tape that exists. We make accessories to install heat tape on almost any kind of roof.

Click here to learn about product specifically for Natural Cedar Roofs

Click Here to lear about products for synthetic cedar roofs

The short answer is NO. Self-regulating heat cable does not turn itself on and off automatically. To do that you need to put the cable on a switched circuit or outlet or on a controller. Of course, you can also be old-school about it and simply plug and unplug as needed. 

“Self-Regulating” refers to the fact that these cables are temperature sensitive. Due to their construction, these cables sense changes in temperature along their entire length, demanding more power as temps fall and less when they rise. 

PipeFreeeze Pro™, Pipe Freeze Protection Solution has a built in thermostatic switch, meaning it will turn on and off on it’s own.

Heat Tape Pro™, does not contain a built-in thermostatic controller. We recommend adding the ThermaCord™ Thermostatic controller to turn your Heat Tape PRO to turn the cable on and off with changes in temperature.

There is no difference.

The terms heat cable, heat tape and heat trace are all used interchangeably to described heated cables used to protect pipes from freezing, preventing roof and gutter ice dams from forming and for safeguarding temperature sensitive components.

Other terms we’ve seen used regarding Heat Tape are:

  • Heat Coils & Heating Coils – Heat Tape has been called this because of the way the zig-zag pattern looks like a heating coil-element (like inside of a toaster)
  • Gutter Trace – Heat Tape get’s called this because of the usage in and around gutters

Radiant Solutions products, including Ice Dam Prevention products such as Heat Tape Pro and Pipe freeze Prevention products like Pipe Freeze Pro can be purchase here at this website or at Amazon.com.

You can install Heat Tape on pretty much any type of roof.

This includes, but is not limited to:

  • Asphalt Shingle
  • Cedar Shakes and Shingles
  • Slate
  • Spanish Tile
  • Metal
  • Flat Roofs (EPDM, TPO, Sprayed Urethane, etc.)

The type of roof you have determines the roof clips and accessories needed. Check out our Heat Tape Installation Accessories.

If you are in need of a specific product that is currently out of stock, you can request to be notified when new inventory of product is in stock.

Click Here to complete the Re-stock Notification Form

We generally do not reserve stock for miscellaneous reasons outside our stated inventory on this website. Besides selling on this website, we also Sell our products on Amazon.com – in doing so, we send separate inventories to their warehouse for fulfillment, so you could check inventory of the product you are looking for there.

Yes. Heat Tape Pro can be used on your flat roof and will not harm the roofing material.

Radiant solutions has developed several accessories and installation components that work well for flat and low-pitch roofs. Installing heat tape on a flat roof often requires more unique considerations than standard serpentine patterns used on pitched roofs.

Check out our Case Studies for examples of Heat Tape installations, including information on flat roofs.

Also refer to the Heat Tape Pro Product Manual for information on flat roof installations of heat tape.