Standing Seam Metal Roof Clips 10-Pack

For Installing Heat Tape on Standing Seam Roofs

10-Pack of Roof Clips for Mounting Heat Tape to Standing Seam Metal Roofs .325″ to .625″.

$24.50

FREE Shipping

Product Details

Standing Seam Metal Roof Clips 10-Pack

This clip comes in three different sizes in packs of 10. The standing seam clip is designed to provide a strong attachment point for installing heat cable on most common standing seam metal roofs. Please verify the width of your standing seam to determine which clip size you need. The standing seam metal roof clip requires a seam with a minimum height of 1 1/4”. Tools Required: Screw gun, Hex head driver bit(5/16”), Butyl Pads(best method for sealing screws), or Silicone caulk.

Clip Facts:

  • UNIVERSAL: Compatible with all manufacturers of ice dam prevention heat tape
  • INCLUDED: 20 Qty Sheet metal screws (2/per clip)
  • CONSTRUCTION: Robust aluminum anodized black. 
  • WARRANTY: Best in the industry 10-year warranty on residential or commercial applications 
  • FAST: Each clip roughly installs in under a minute when using our butyl pads

Important:

  • .325″ Standing Seam metal roof clips should only be used on standing seams between ⅛” and ⅜.”
  • .500″ Standing Seam metal roof clips should only be used on standing seams between ¼” and ½.”
  • .625″ Standing Seam metal roof clips should only be used on standing seams between ½” and ⅝.”
5/5

“Heat Tape Pro did exactly what I needed it to do. Now I don’t have to worry about water leaking into my house, because I can tell when it’s working by the little light on the end of the cable.”

-Michael P.
Amazon Customer

4/5

“This heat tape works as advertised. It was delivered to me fast, and although it’s a little complicated to install, the documentation is good..”

-Shaun D.
Radiant Solutions Customer

5/5

“I install thousands of feet of heat tape every year. This is the best stuff I’ve found to protect my customers homes and give them the piece of mind they need.”

-Patrick B.
Professional Installer

Frequently Asked Questions

If the product you need is currently out of stock, don’t worry. 

We are frequently restocking products and the one you need will soon be available. You can make a request to be notified when out of stock items are re-stocked. 

Click Here to Submit your information to be notified of a Products Restock

Yes. Heat Tape Pro can be used on your flat roof and will not harm the roofing material.

Radiant solutions has developed several accessories and installation components that work well for flat and low-pitch roofs. Installing heat tape on a flat roof often requires more unique considerations than standard serpentine patterns used on pitched roofs.

Check out our Case Studies for examples of Heat Tape installations, including information on flat roofs.

Also refer to the Heat Tape Pro Product Manual for information on flat roof installations of heat tape.

Here’s a handy guide that explains the steps of measuring so you know which length of heat tape to get.

Measuring the area of your roof that is affected by ice dams so you know how much heat tape to get is not overly complex, but it does have a few variables. Use our Heat Tape Measuring Guide to understand the process and print a worksheet that you can use to make sure you have all the right numbers.

Once you have all the measurements and considerations you need, use our Heat Tape Calculator to calculate the size of heat tape you should get.

The short answer is NO. Self-regulating heat cable does not turn itself on and off automatically. To do that you need to put the cable on a switched circuit or outlet or on a controller. Of course, you can also be old-school about it and simply plug and unplug as needed. 

“Self-Regulating” refers to the fact that these cables are temperature sensitive. Due to their construction, these cables sense changes in temperature along their entire length, demanding more power as temps fall and less when they rise. 

PipeFreeeze Pro™, Pipe Freeze Protection Solution has a built in thermostatic switch, meaning it will turn on and off on it’s own.

Heat Tape Pro™, does not contain a built-in thermostatic controller. We recommend adding the ThermaCord™ Thermostatic controller to turn your Heat Tape PRO to turn the cable on and off with changes in temperature.

Yes We Do. However, it is fairly costly.

We have a calculated rate based on the product in your cart if you choose to ship to Canada or Alaska.
More can be found here.

Yes!

And if you are using Heat Tape Pro on your roof / eave to resolve an ice dam issue, you should use heat tape to make sure there’s a clear path through your gutters for water to escape your roof. If you don’t do that, the water could just refreeze in your gutters. You also want to get the downspouts too.

Be careful if you plan on using heat tape Only in your gutters.

There is a common misconception that gutters are a root cause of ice dams. This misconception can lead people astray when creating their strategy for ice dam deterrence. If you have an overhang on your roof (an eave), the chances are very good that you problem exists on your roof before the gutter.

Learn More about How Ice Dams Form Here

Yes!

Installing our heat tape on your standing seam roof can be very effective in combating ice dam formation. There’s two main products used to install heat tape on your standing seam metal roof: The S-5 SR Heat Tape Clip, and the standard ice dam heat tape clip.

S-5 SR Clip for Heat Tape & Standing Seam Roofs

Installing Heat Tape on a Standing Seam Roof with the S-5 SR Heat Tape Clip
The S-5 Heat Tape Roof Clip is a new, patented roof clip design specifically for standing seam applications with a focus on ease of install and effectiveness. It is used in conjunction with the S-5 Base, which needs to be purchased separately. The S-5 base is designed to clamp onto the seam of a metal roof as the S-5 Clip holds your ice dam heat tape into position. Can be set up in a single or dual-clip configuration. (See product page for more info)


Installing Heat Tape on a Standing Seam Roof with Standard Roof Clips

There are specific ways/configurations used when installing heat tape on a standing seam / metal roof using standard heat tape clips. The following (2.6 – figure 16.0 & 17.0) shows a snippet of the HeatTape Pro installation manual showing two different clip configurations, more info can be found in the manual itself: Heat Tape Pro installation Manual