Remote Display Panel Extender

Extend CDP-2 to 50, 100, 200 Feet Away

Use to wire a CDP-2 display panel on to a convenient viewing location, 50 Feet of #20 AWG 6 Conductor wire, silver tinning shielded and insulated for 300 volts to eliminate interference and increase safety.

  • For use with the CDP-2 heat cable system display panel
  • 50,100,200 feet cable length options
  • Shielded for ultimate high noise immunity
  • 300 volt jacketing insulation rating for safety next to line voltage wiring

$70.49$240.57

FREE Shipping

Product Details

Remote Display Panel Extender

The primary connection between an ASE DS8 and DS9 Heat Cable Controllers and a CDP-2 remote monitor interface is an cable of superior quality and reliability. When exposed to outdoor conditions cheap cables (such as CAT 5)  tend to deteriorate rapidly, leading to erratic and unreliable sensor performance. Similarly, using telephone wire, thermostat wire, or other cheap alternatives will also yield subpar results with the sensor.

5/5

“Heat Tape Pro did exactly what I needed it to do. Now I don’t have to worry about water leaking into my house, because I can tell when it’s working by the little light on the end of the cable.”

-Michael P.
Amazon Customer

4/5

“This heat tape works as advertised. It was delivered to me fast, and although it’s a little complicated to install, the documentation is good..”

-Shaun D.
Radiant Solutions Customer

5/5

“I install thousands of feet of heat tape every year. This is the best stuff I’ve found to protect my customers homes and give them the piece of mind they need.”

-Patrick B.
Professional Installer

Frequently Asked Questions

Yes!

Installing our heat tape on your standing seam roof can be very effective in combating ice dam formation. There’s two main products used to install heat tape on your standing seam metal roof: The S-5 SR Heat Tape Clip, and the standard ice dam heat tape clip.

S-5 SR Clip for Heat Tape & Standing Seam Roofs

Installing Heat Tape on a Standing Seam Roof with the S-5 SR Heat Tape Clip
The S-5 Heat Tape Roof Clip is a new, patented roof clip design specifically for standing seam applications with a focus on ease of install and effectiveness. It is used in conjunction with the S-5 Base, which needs to be purchased separately. The S-5 base is designed to clamp onto the seam of a metal roof as the S-5 Clip holds your ice dam heat tape into position. Can be set up in a single or dual-clip configuration. (See product page for more info)


Installing Heat Tape on a Standing Seam Roof with Standard Roof Clips

There are specific ways/configurations used when installing heat tape on a standing seam / metal roof using standard heat tape clips. The following (2.6 – figure 16.0 & 17.0) shows a snippet of the HeatTape Pro installation manual showing two different clip configurations, more info can be found in the manual itself: Heat Tape Pro installation Manual

The short answer is NO. Self-regulating heat cable does not turn itself on and off automatically. To do that you need to put the cable on a switched circuit or outlet or on a controller. Of course, you can also be old-school about it and simply plug and unplug as needed. 

“Self-Regulating” refers to the fact that these cables are temperature sensitive. Due to their construction, these cables sense changes in temperature along their entire length, demanding more power as temps fall and less when they rise. 

PipeFreeeze Pro™, Pipe Freeze Protection Solution has a built in thermostatic switch, meaning it will turn on and off on it’s own.

Heat Tape Pro™, does not contain a built-in thermostatic controller. We recommend adding the ThermaCord™ Thermostatic controller to turn your Heat Tape PRO to turn the cable on and off with changes in temperature.

Orders are generally fulfilled within a business day of your purchase. Delivery times depend on where you are in the U.S.

heat tape shipping times

Free Shipping

The Free Shipping option uses available “standard” delivery methods for whichever carrier services your location. For many that means UPS ground, but for locations that UPS doesn’t go to –or is too expensive, we substitute a different carrier. 

We are based in the Twin Cities (Minneapolis/St. Paul) metro area, so depending on where you are located, your shipping time will vary.

Here’s A link to shipping distances with Approximations of Lead times

2-Day Shipping

If you can’t wait for your product to arrive via UPS ground, Radiant Solutions also offers a paid, 2-day shipping option. One thing to keep in mind: our cables are fairly heavy, which mean they are expensive for us to ship. This means that they are even more expensive to ship expeditiously. A little bit of planning ahead can save you some good money.

Yes. Radiant Solutions Company is based in Hopkins, Minnesota.

We are a family-owned business with less than 10 employees that has been in business since 2016. Our experience with ice dams goes far beyond that: our founder Steve started a business diagnosing and solving Ice Dam problems on customer houses for almost 35 years.

Yes. Heat Tape Pro can be used on your flat roof and will not harm the roofing material.

Radiant solutions has developed several accessories and installation components that work well for flat and low-pitch roofs. Installing heat tape on a flat roof often requires more unique considerations than standard serpentine patterns used on pitched roofs.

Check out our Case Studies for examples of Heat Tape installations, including information on flat roofs.

Also refer to the Heat Tape Pro Product Manual for information on flat roof installations of heat tape.

Yes!

And if you are using Heat Tape Pro on your roof / eave to resolve an ice dam issue, you should use heat tape to make sure there’s a clear path through your gutters for water to escape your roof. If you don’t do that, the water could just refreeze in your gutters. You also want to get the downspouts too.

Be careful if you plan on using heat tape Only in your gutters.

There is a common misconception that gutters are a root cause of ice dams. This misconception can lead people astray when creating their strategy for ice dam deterrence. If you have an overhang on your roof (an eave), the chances are very good that you problem exists on your roof before the gutter.

Learn More about How Ice Dams Form Here

We don’t install heat tape, but we know who does.

We work with licensed roofers, electricians and other contractors as Installers of Radiant Solutions Products. We know of installers all over the country.

If you are interested in finding a Heat Tape PRO™ installer in your area, click here to submit your info. If we have an installer we know of in your area, we will send you a recommendation.