Standing Seam Metal Roof Clips 10-Pack

For Installing Heat Tape on Standing Seam Roofs

10-Pack of Roof Clips for Mounting Heat Tape to Standing Seam Metal Roofs .325″ to .625″.

$24.50

FREE Shipping

Product Details

Standing Seam Metal Roof Clips 10-Pack

This clip comes in three different sizes in packs of 10. The standing seam clip is designed to provide a strong attachment point for installing heat cable on most common standing seam metal roofs. Please verify the width of your standing seam to determine which clip size you need. The standing seam metal roof clip requires a seam with a minimum height of 1 1/4”. Tools Required: Screw gun, Hex head driver bit(5/16”), Butyl Pads(best method for sealing screws), or Silicone caulk.

Clip Facts:

  • UNIVERSAL: Compatible with all manufacturers of ice dam prevention heat tape
  • INCLUDED: 20 Qty Sheet metal screws (2/per clip)
  • CONSTRUCTION: Robust aluminum anodized black. 
  • WARRANTY: Best in the industry 10-year warranty on residential or commercial applications 
  • FAST: Each clip roughly installs in under a minute when using our butyl pads

Important:

  • .325″ Standing Seam metal roof clips should only be used on standing seams between ⅛” and ⅜.”
  • .500″ Standing Seam metal roof clips should only be used on standing seams between ¼” and ½.”
  • .625″ Standing Seam metal roof clips should only be used on standing seams between ½” and ⅝.”
5/5

“Heat Tape Pro did exactly what I needed it to do. Now I don’t have to worry about water leaking into my house, because I can tell when it’s working by the little light on the end of the cable.”

-Michael P.
Amazon Customer

4/5

“This heat tape works as advertised. It was delivered to me fast, and although it’s a little complicated to install, the documentation is good..”

-Shaun D.
Radiant Solutions Customer

5/5

“I install thousands of feet of heat tape every year. This is the best stuff I’ve found to protect my customers homes and give them the piece of mind they need.”

-Patrick B.
Professional Installer

Frequently Asked Questions

Yes We Do. However, it is fairly costly.

We have a calculated rate based on the product in your cart if you choose to ship to Canada or Alaska.
More can be found here.

Yes. Radiant Solutions Company is based in Hopkins, Minnesota.

We are a family-owned business with less than 10 employees that has been in business since 2016. Our experience with ice dams goes far beyond that: our founder Steve started a business diagnosing and solving Ice Dam problems on customer houses for almost 35 years.

Including a thermostatic heat tape switch or controller in your installation will cut power to your heat tape in times it is not needed. This will lessen your environmental footprint and save you money.

Savings will always depend on the weather and how often you have temperatures above the threshold that the switch turns on your heat cable. In most situations where heat cable is needed, savings will offset the cost of the ThermaCord and then some.

Yes. Heat Tape Pro can be used on your flat roof and will not harm the roofing material.

Radiant solutions has developed several accessories and installation components that work well for flat and low-pitch roofs. Installing heat tape on a flat roof often requires more unique considerations than standard serpentine patterns used on pitched roofs.

Check out our Case Studies for examples of Heat Tape installations, including information on flat roofs.

Also refer to the Heat Tape Pro Product Manual for information on flat roof installations of heat tape.

You can install Heat Tape on pretty much any type of roof.

This includes, but is not limited to:

  • Asphalt Shingle
  • Cedar Shakes and Shingles
  • Slate
  • Spanish Tile
  • Metal
  • Flat Roofs (EPDM, TPO, Sprayed Urethane, etc.)

The type of roof you have determines the roof clips and accessories needed. Check out our Heat Tape Installation Accessories.

There is no difference.

The terms heat cable, heat tape and heat trace are all used interchangeably to described heated cables used to protect pipes from freezing, preventing roof and gutter ice dams from forming and for safeguarding temperature sensitive components.

Other terms we’ve seen used regarding Heat Tape are:

  • Heat Coils & Heating Coils – Heat Tape has been called this because of the way the zig-zag pattern looks like a heating coil-element (like inside of a toaster)
  • Gutter Trace – Heat Tape get’s called this because of the usage in and around gutters

Yes!

Installing our heat tape on your standing seam roof can be very effective in combating ice dam formation. There’s two main products used to install heat tape on your standing seam metal roof: The S-5 SR Heat Tape Clip, and the standard ice dam heat tape clip.

S-5 SR Clip for Heat Tape & Standing Seam Roofs

Installing Heat Tape on a Standing Seam Roof with the S-5 SR Heat Tape Clip
The S-5 Heat Tape Roof Clip is a new, patented roof clip design specifically for standing seam applications with a focus on ease of install and effectiveness. It is used in conjunction with the S-5 Base, which needs to be purchased separately. The S-5 base is designed to clamp onto the seam of a metal roof as the S-5 Clip holds your ice dam heat tape into position. Can be set up in a single or dual-clip configuration. (See product page for more info)


Installing Heat Tape on a Standing Seam Roof with Standard Roof Clips

There are specific ways/configurations used when installing heat tape on a standing seam / metal roof using standard heat tape clips. The following (2.6 – figure 16.0 & 17.0) shows a snippet of the HeatTape Pro installation manual showing two different clip configurations, more info can be found in the manual itself: Heat Tape Pro installation Manual

Radiant Solutions products, including Ice Dam Prevention products such as Heat Tape Pro and Pipe freeze Prevention products like Pipe Freeze Pro can be purchase here at this website or at Amazon.com.