Remote Sensor Extension Kit (EX-50)

Extend the Range of your DS8 & DS9 Moisture Sensor

Our Remote Precipitation Sensor Extension Kit extends the DS8 and DS9 remote precipitation sensors up to an additional 50 feet from the controller enclosure and includes an IP67 watertight connector

  • 20 AWG 6 wire cable
  • Shielded for high noise immunity
  • 300 volt insulation rating for safe installation next to line voltage wires
  • Requires no special tools for installation
  • Shielded for high noise immunity

$127.15

14 in stock

FREE Shipping

Product Details

Remote Sensor Extension Kit (EX-50)

The EX-50 is manufactured from cable identical to that used in the remote precipitation sensor. Matching outside diameter means a solid, watertight seal when passed through the top-mount strain relief of the sensor enclosure. The cable comes pre-terminated with a watertight circular connector. The included mating connector can be installed on the end of the sensor cable using standard hand tools. No special crimp tools or soldering is required! And, once mated, the M12 circular connectors provide a rugged IP67-rated watertight connection. The special connector provided also allows extending the cable shield, improving noise immunity and preventing false triggering.



5/5

“Heat Tape Pro did exactly what I needed it to do. Now I don’t have to worry about water leaking into my house, because I can tell when it’s working by the little light on the end of the cable.”

-Michael P.
Amazon Customer

4/5

“This heat tape works as advertised. It was delivered to me fast, and although it’s a little complicated to install, the documentation is good..”

-Shaun D.
Radiant Solutions Customer

5/5

“I install thousands of feet of heat tape every year. This is the best stuff I’ve found to protect my customers homes and give them the piece of mind they need.”

-Patrick B.
Professional Installer

Frequently Asked Questions

Including a thermostatic heat tape switch or controller in your installation will cut power to your heat tape in times it is not needed. This will lessen your environmental footprint and save you money.

Savings will always depend on the weather and how often you have temperatures above the threshold that the switch turns on your heat cable. In most situations where heat cable is needed, savings will offset the cost of the ThermaCord and then some.

The short answer is NO. Self-regulating heat cable does not turn itself on and off automatically. To do that you need to put the cable on a switched circuit or outlet or on a controller. Of course, you can also be old-school about it and simply plug and unplug as needed. 

“Self-Regulating” refers to the fact that these cables are temperature sensitive. Due to their construction, these cables sense changes in temperature along their entire length, demanding more power as temps fall and less when they rise. 

PipeFreeeze Pro™, Pipe Freeze Protection Solution has a built in thermostatic switch, meaning it will turn on and off on it’s own.

Heat Tape Pro™, does not contain a built-in thermostatic controller. We recommend adding the ThermaCord™ Thermostatic controller to turn your Heat Tape PRO to turn the cable on and off with changes in temperature.

Yes We Do. However, it is fairly costly.

We have a calculated rate based on the product in your cart if you choose to ship to Canada or Alaska.
More can be found here.

Yes!

Installing our heat tape on your standing seam roof can be very effective in combating ice dam formation. There’s two main products used to install heat tape on your standing seam metal roof: The S-5 SR Heat Tape Clip, and the standard ice dam heat tape clip.

S-5 SR Clip for Heat Tape & Standing Seam Roofs

Installing Heat Tape on a Standing Seam Roof with the S-5 SR Heat Tape Clip
The S-5 Heat Tape Roof Clip is a new, patented roof clip design specifically for standing seam applications with a focus on ease of install and effectiveness. It is used in conjunction with the S-5 Base, which needs to be purchased separately. The S-5 base is designed to clamp onto the seam of a metal roof as the S-5 Clip holds your ice dam heat tape into position. Can be set up in a single or dual-clip configuration. (See product page for more info)


Installing Heat Tape on a Standing Seam Roof with Standard Roof Clips

There are specific ways/configurations used when installing heat tape on a standing seam / metal roof using standard heat tape clips. The following (2.6 – figure 16.0 & 17.0) shows a snippet of the HeatTape Pro installation manual showing two different clip configurations, more info can be found in the manual itself: Heat Tape Pro installation Manual

There is no difference.

The terms heat cable, heat tape and heat trace are all used interchangeably to described heated cables used to protect pipes from freezing, preventing roof and gutter ice dams from forming and for safeguarding temperature sensitive components.

Other terms we’ve seen used regarding Heat Tape are:

  • Heat Coils & Heating Coils – Heat Tape has been called this because of the way the zig-zag pattern looks like a heating coil-element (like inside of a toaster)
  • Gutter Trace – Heat Tape get’s called this because of the usage in and around gutters
Here’s a handy guide that explains the steps of measuring so you know which length of heat tape to get.

Measuring the area of your roof that is affected by ice dams so you know how much heat tape to get is not overly complex, but it does have a few variables. Use our Heat Tape Measuring Guide to understand the process and print a worksheet that you can use to make sure you have all the right numbers.

Once you have all the measurements and considerations you need, use our Heat Tape Calculator to calculate the size of heat tape you should get.

Orders are generally fulfilled within a business day of your purchase. Delivery times depend on where you are in the U.S.

heat tape shipping times

Free Shipping

The Free Shipping option uses available “standard” delivery methods for whichever carrier services your location. For many that means UPS ground, but for locations that UPS doesn’t go to –or is too expensive, we substitute a different carrier. 

We are based in the Twin Cities (Minneapolis/St. Paul) metro area, so depending on where you are located, your shipping time will vary.

Here’s A link to shipping distances with Approximations of Lead times

2-Day Shipping

If you can’t wait for your product to arrive via UPS ground, Radiant Solutions also offers a paid, 2-day shipping option. One thing to keep in mind: our cables are fairly heavy, which mean they are expensive for us to ship. This means that they are even more expensive to ship expeditiously. A little bit of planning ahead can save you some good money.

You can install Heat Tape on pretty much any type of roof.

This includes, but is not limited to:

  • Asphalt Shingle
  • Cedar Shakes and Shingles
  • Slate
  • Spanish Tile
  • Metal
  • Flat Roofs (EPDM, TPO, Sprayed Urethane, etc.)

The type of roof you have determines the roof clips and accessories needed. Check out our Heat Tape Installation Accessories.